Ringlock Scaffolding Dimensions, Component Sizes and Weight Chart

ringlock scaffolding dimensions for construction projects

When buying ringlock scaffolding, dimensions matter more than the product name alone. Two suppliers may both list a “48.3 mm ringlock system,” but differences in rosette spacing, ledger length, wall thickness or connection details can make components incompatible.

This guide summarizes the steel and aluminum ringlock sizes currently supplied by Bythai. It covers standards, ledgers and diagonal braces, with the corresponding lengths and net weights. Use the tables for an initial comparison, then confirm the connection drawing and tolerances before approving a production order.

Ringlock Scaffolding Dimensions at a Glance

The steel data in the current Bythai product sheet uses the M48 designation.

  • Steel standards: M48 × 3.2 mm
  • Steel ledgers: M48 × 3.0 mm
  • Steel diagonal braces: M48 × 2.75 mm
  • Surface treatment shown in the supplied data: HDG (hot-dip galvanized)

Available lengths vary by component. For an RFQ, always write the component name together with the required length.

For example, a 2,000 mm standard, a 2,000 mm ledger, and a 2,000 × 2,000 mm diagonal brace are three different products.

What to Confirm Before Comparing Suppliers

  • Outside diameter and wall thickness
  • Rosette spacing and hole pattern
  • Spigot length and connection method
  • Ledger-head and brace-head dimensions
  • Steel grade and material certificate
  • Surface treatment and coating requirement
  • Net weight, gross packed weight and tolerance

The Bythai Ringlock System page shows the main system layout and product groups.

Ringlock Standard Dimensions and Weight Chart

Standards set the vertical lift height and connect to base collars, ledgers, braces and upper standards. These are the steel sizes and net weights listed in the supplied catalog data.

SpecificationThicknessLengthSurfaceNet weight
M483.2 mm500 mmHDG2.56 kg
M483.2 mm1,000 mmHDG4.99 kg
M483.2 mm1,500 mmHDG7.45 kg
M483.2 mm2,000 mmHDG9.95 kg
M483.2 mm2,500 mmHDG12.43 kg
M483.2 mm3,000 mmHDG14.87 kg

Use these figures when checking a quotation or planning a container. The final shipping weight will also include packaging, fittings and normal production tolerance.

For the available product configuration, see the Ringlock Standards and verticals. Ask for the drawing if you need to match an existing fleet.

Standard Connection Checks

Before ordering replacement standards, confirm the rosette position, rosette spacing, spigot detail and actual outside diameter. The M48 label alone is not enough to prove that two systems will fit.

Ringlock Ledger Dimensions and Weight Chart

Ledgers define the bay length and support the working platform. A small difference in length can change the platform layout, brace geometry and the number of standards required.

SpecificationThicknessLengthSurfaceNet weight
M483.0 mm600 mmHDG2.35 kg
M483.0 mm900 mmHDG3.23 kg
M483.0 mm1,219 mmHDG4.17 kg
M483.0 mm1,800 mmHDG5.88 kg
M483.0 mm1,829 mmHDG5.95 kg
M483.0 mm2,000 mmHDG6.45 kg
M483.0 mm2,500 mmHDG7.88 kg

The 1,800 mm and 1,829 mm ledgers are separate catalog items. Do not substitute one for the other until the bay drawing and platform dimensions have been checked.

You can compare the available lengths on the Ringlock Ledger product page. Include your existing ledger-head photo or a sample measurement when requesting a match.

How to Select a Ledger Length

Check the bay length, plank length, working load, diagonal-brace size and available inventory together. The longest ledger is not automatically the most economical option. A shorter bay may reduce platform waste or suit a tight facade better.

Ringlock Diagonal Brace Dimensions and Weight Chart

Diagonal braces control lateral movement. The first number in the table represents one plan dimension and the second represents the other dimension shown in the supplier sheet. Confirm the notation on the approved drawing before production.

SpecificationThicknessLengthSurfaceNet weight
M482.75 mm1,500 × 2,000 mmHDG9.87 kg
M482.75 mm2,000 × 1,219 mmHDG9.50 kg
M482.75 mm2,000 × 2,000 mmHDG10.55 kg
M482.75 mm2,000 × 2,500 mmHDG11.78 kg

Brace selection depends on bay length, lift height and the rosette connection. A brace that looks close in length may still place the brace head under stress if the geometry is different.

The Ringlock Diagonal product page can be used as the product reference in your RFQ.

Ringlock Component Compatibility Checklist

When replacing or extending an existing steel ringlock system, request a dimensioned drawing or connection sample before placing the order.

Steel-to-Steel Compatibility Checks

Check the following dimensions:

  • Outside tube diameter
  • Wall thickness
  • Rosette diameter
  • Rosette spacing
  • Rosette hole pattern
  • Spigot dimensions
  • Ledger head
  • Wedge
  • Brace head
  • Connection tolerances

Matching only the tube diameter is not enough.

For example, two products may both use an M48 tube while having different rosette spacing or connection details. In that case, the components may not connect correctly.

Why Connection Details Matter

Ringlock components work as a system. Standards, ledgers, transoms, braces, base collars, jacks, and other accessories need to match the connection geometry used by the system.

If you are replacing only one component in an existing scaffold fleet, send the supplier:

  1. A photo of the connection
  2. Outside diameter measurement
  3. Wall thickness
  4. Rosette spacing
  5. Existing component length
  6. A drawing or sample if available

This gives the supplier enough information to check the required configuration before production.


Ringlock RFQ Checklist

When requesting a quotation for steel ringlock scaffolding, provide the following information:

  • Component name
  • Required quantity
  • Tube diameter
  • Wall thickness
  • Required length
  • Surface treatment
  • Steel grade
  • Destination country and port
  • Existing drawing or connection photo
  • Required inspection or test documents
  • Packaging requirements
  • Target shipment date

For example, instead of writing:

Ringlock standard — 500 pcs

a clearer RFQ would be:

Steel Ringlock Standard — M48 × 3.2 mm × 2,000 mm — HDG — 500 pcs

This reduces the chance of specification misunderstandings during quotation and production.


Ringlock Scaffolding Dimensions and Project Quantity

Component dimensions are also important when calculating the quantity required for a project.

For example, if a project uses:

  • 2,500 mm ledger length
  • 2,000 mm standard length
  • Two standard rows
  • 30 m facade length
  • 10 m scaffold height

The basic grid calculation is:

Bays:

30 ÷ 2.5 = 12 bays

Lifts:

10 ÷ 2.0 = 5 lifts

Standard positions along the facade:

12 + 1 = 13 positions

Total standard pieces for two rows:

13 × 2 × 5 = 130 pieces

The actual quantities of transoms, diagonal braces, boards, base jacks, guardrails, and other components depend on the approved scaffold layout.

For a detailed calculation method, see our guide on How to Calculate Ringlock Scaffolding Quantity: A Practical BOQ Guide.


Need a Ringlock Scaffolding Quote?

Send us your component list, required dimensions, quantities, and destination port.

If you are matching an existing steel ringlock system, include a drawing, connection photo, or sample dimensions. Our team can check the specifications and prepare a project-specific quotation.

Request a Ringlock Scaffolding Quote


FAQ: Ringlock Scaffolding Dimensions

What are the standard ringlock scaffolding dimensions?

There is no single size for every ringlock system. In the Bythai steel data, standards use M48 × 3.2 mm, ledgers use M48 × 3.0 mm, and diagonal braces use M48 × 2.75 mm. Available lengths vary by component.

What standard lengths are available?

The Bythai steel ringlock standard data includes 500 mm, 1,000 mm, 1,500 mm, 2,000 mm, 2,500 mm, and 3,000 mm lengths.

What ledger lengths are available?

The steel ledger data includes 600 mm, 900 mm, 1,219 mm, 1,800 mm, 1,829 mm, 2,000 mm, and 2,500 mm lengths.

Can I use a 1,829 mm ledger instead of a 1,800 mm ledger?

Not without checking the bay drawing, platform dimensions, brace geometry, and existing connection system. They are separate catalog items and should not be treated as interchangeable automatically.

Does the M48 designation guarantee compatibility?

No. The M48 designation identifies the tube size used in the product data, but compatibility also depends on rosette dimensions, spacing, spigots, ledger heads, brace heads, and other connection details.

What should I check when matching an existing ringlock system?

Check the tube diameter, wall thickness, rosette spacing, rosette hole pattern, spigot dimensions, ledger-head dimensions, brace-head dimensions, and component lengths. A drawing, sample, or connection photo can help the supplier confirm compatibility.

What documents should I request before shipment?

Depending on the project requirements, request the final specification sheet, material certificate, dimensional inspection records, surface-treatment details, and any required test or third-party inspection reports.

Disclaimer

The dimensions and weights in this article are based on Bythai’s current supplied steel ringlock catalog data and are intended for product comparison, quotation, and purchasing discussions.

They are not a scaffold design, load calculation, or site approval. A qualified person must verify the final configuration against project drawings, applicable regulations, manufacturer instructions, working loads, and site conditions before installation or use.

You might also like