Acrow Prop Sizes 0-4: Height, Weight and Load Selection Guide

When comparing acrow prop sizes, start with the working height, not the Size 0-4 label. Acrow Size 0, 1, 2, 3 and 4 are common trade terms, but the numbering is not a universal specification. BYTHAI offers adjustable steel props covering approximately 0.6 m to 6.0 m, with different tube combinations and duty ratings. This article compares the height ranges and explains what to check before sending a quotation request.

Acrow prop sizes components: steel props, collar nut, sleeve, end plate and G‑pin spare parts

Quick Acrow Prop Size Chart

The table uses the height ranges currently shown on BYTHAI product pages. It is a procurement shortlist, not a load table.

BYTHAI product typePublished height rangesInner tubeOuter tubeCatalogue wall thickness
Light duty0.6-1.1 m; 0.8-1.4 m; 1.6-2.9 m; 1.8-3.2 m; 2.0-3.6 m; 2.2-4.0 m40 mm48 mm1.6-2.4 mm
Middle duty1.8-3.2 m; 2.0-3.5 m; 2.0-3.6 m; 2.2-4.0 m48 mm56 mm1.6-2.4 mm
Heavy duty1.6-2.9 m; 1.8-3.2 m; 2.0-3.5 m; 2.0-3.6 m; 2.2-4.0 m; 3.0-5.0 m; 3.5-6.0 m48 mm60 mm1.6-2.4 mm

The 40/48 mm, 48/56 mm and 48/60 mm combinations above are the main combinations shown for light-, middle- and heavy-duty props. The catalogue also lists 76 mm and 89 mm outer tubes for heavy-duty custom projects. Confirm the exact inner and outer tube combination on the drawing.

This table lists dimension ranges only, NOT safe working load data.

Height to recommended prop type

This second table makes the overlap easier to see. Where two types are shown, the design load and site conditions decide the final choice.

Required heightFirst product type to checkWhy / what to compare
0.6-1.4 mLight dutyThe short light-duty bands are the closest match.
1.6-2.9 mLight or heavy dutySame height is listed in both; compare load and tube section.
1.8-3.2 mLight or middle dutyCompare 40/48 mm with 48/56 mm tubes.
2.0-4.0 mMiddle or heavy dutySeveral bands overlap; use the approved prop schedule.
3.0-5.0 mHeavy dutyOnly the heavy-duty page lists this band.
3.5-6.0 mHeavy dutyThe longest BYTHAI range; obtain a model drawing.

What Acrow Prop Sizes 0-4 Actually Mean

The numbers are common trade shorthand, not a unified international standard. One supplier’s Size 2 may not match another’s height, thread or plate. Convert the number into measurements before ordering.

The Size 0-4 mapping below is a practical starting point for inquiries, not an official BYTHAI size classification. Because Acrow prop size numbers are not universally standardized, always confirm the actual minimum and maximum working height before ordering.

Market term in an inquiryBYTHAI height band to check firstPurchasing note
Acrow prop size 00.6-1.1 m or 0.8-1.4 mStart with the light-duty range and confirm the end plate.
Acrow prop size 11.6-2.9 m or 1.8-3.2 mCompare light-, middle- and heavy-duty sections at the required height.
Acrow prop size 22.0-3.5 m, 2.0-3.6 m or 2.2-4.0 mLeave adjustment travel and provide the design load.
Acrow prop size 32.2-4.0 m or 3.0-5.0 mCheck alignment, bearing and lateral restraint.
Acrow prop size 43.5-6.0 mStart with the heavy-duty range and request the model drawing.

Compare BYTHAI’s light-duty adjustable steel props, middle-duty shoring props and heavy-duty telescopic props by actual height and tube specification. Do not place an order from the trade number alone.

Why Acrow Prop Weight Varies by Model

The trade label does not tell a warehouse the finished weight. Weight changes with:

  • Inner and outer tube diameter and wall thickness
  • Q235 or Q355B steel grade
  • End-plate size and thickness
  • Collar nut, handle, sleeve and G-pin
  • Welded details and surface treatment

The supplied product information does not give a net weight for each Size 0-4 label. For freight and rental inventory, request the net weight per prop, gross weight per bundle, bundle dimensions and pieces per bundle. Use the finished model, not a generic online weight chart, for container calculations.

Load Capacity and Extension

Height alone cannot establish capacity. Extension increases unsupported length; end restraint, plumb, bearing and eccentric loading also matter.

Give BYTHAI the design load and working height. The quotation should define whether the value is characteristic resistance, design resistance or permissible load, together with its test or calculation basis. Important: working load drops significantly as you extend the prop to its maximum height. Never run props at full extension for heavy-load applications.

For EN 1065 background, use the official BSI EN 1065 catalogue record. The catalogue entry does not replace a model-specific resistance report.

Selection Method for Adjustable Steel Prop Sizes

1. Measure the installed height

Measure from the bearing surface to the underside of the beam or formwork. Record minimum and maximum heights.

2. Match the tube section

The common combinations are 40/48 mm for light duty, 48/56 mm for middle duty and 48/60 mm for heavy duty. They are not the only choices. The catalogue also lists 76 mm and 89 mm large-diameter tubes for custom heavy-duty projects. Confirm the inner tube, outer tube, wall thickness and overlap on the final drawing.

3. Check the adjustment parts

Specify the collar nut, thread, G-pin, sleeve and end plate. A replacement must fit the existing equipment, not only match its height.

4. Match the finish to the job

BYTHAI offers painted, powder-coated, electro-galvanized, pre-galvanized and hot-dip galvanized finishes. Painted finishes may suit dry indoor work; galvanized options suit more demanding exposure.

Packing Quantities and RFQ Checklist

Packing quantities are not shown on the public pages. Request these with the quotation:

  • Actual minimum and maximum working height
  • Quantity by height band and duty type
  • Q235 or Q355B steel
  • Inner and outer tube diameter and wall thickness
  • End-plate, collar, pin and thread details
  • Surface treatment
  • Required resistance or approved design load
  • Net weight, gross bundle weight and pieces per bundle
  • Bundle dimensions and destination port
  • EN 1065 documents, if required by the project

Send the list through the BYTHAI steel prop quotation page, and attach a drawing or sample dimensions when matching an existing system.

For U.S. work, consult the official OSHA formwork and shoring requirements. UK teams can refer to the HSE formwork guidance. These are safety references, not universal prop load tables.

Need an Acrow Prop Quote?

If you are comparing these prop options, send the actual height, quantity, tube specification, finish and destination port. BYTHAI can match the request to a light-, middle- or heavy-duty configuration and return the model drawing, weight and resistance documents available for that item.

FAQ

What height ranges do Acrow props cover?

There is no unified international Size 0-4 standard. Many buyers in Africa, the Middle East and Southeast Asia still order using Size 0-4 names. Always translate the trade label into exact height and tube specifications before placing an order. BYTHAI’s published bands run from 0.6-1.1 m to 3.5-6.0 m.

What is the difference between Acrow prop sizes 0, 1, 2, 3 and 4?

The main difference is the typical working-height range associated with each trade term. Size 0-4 is not a universal standard, so confirm the exact height, tube specification and load requirement with the supplier.

How do I choose the right Acrow prop size?

Start with the required working height, then check the tube section, extension range, required load, end restraint and site conditions. Do not select a prop from the Size 0-4 label alone.

What does an acrow prop size chart normally show?

Most third-party Acrow prop charts list market size numbers, height ranges and tube specifications. Some include weight or load figures. Verify load data against the actual manufacturer’s report; do not rely on a generic online chart.

Can I use an acrow prop size 0 from another supplier with BYTHAI parts?

Not based on the number alone. Compare the tube diameter, wall, thread, pin holes, collar, end plate and overlap. Send a drawing or sample measurement before ordering replacement parts.

Why is the weight different between two props with the same height?

Tube thickness, steel grade, plates, collar, pins, welds and finish can all change the finished weight. Ask for model net and packed shipping weight.

Can maximum height be used as the load rating?

No. Extension, alignment, end restraint, bearing and the steel section all affect resistance. Use the value issued for the installed height and quoted model.

Does BYTHAI offer different surface treatments?

Yes. The catalogue lists painted, powder-coated, electro-galvanized, pre-galvanized and hot-dip galvanized options. State your selected finish when sending your inquiry.

Disclaimer

This article supports product comparison and RFQ preparation. It is not a shoring design, certified load table or approval for site use. Before installation, a licensed or otherwise locally qualified temporary-works engineer must check the prop model, extension, spacing, bracing, bearing and working load against the project drawings, local regulations and current BYTHAI technical documents.

You might also like